Thank you all for your quick response's, they are immensely appreciated.

I had a gut feeling these were the answer's...

-----Original Message-----
From: Roger Stoops [mailto:[log in to unmask]] 
Sent: Thursday, September 21, 2006 11:47 AM
To: TechNet E-Mail Forum; Abel, Shannon K.
Subject: RE: [TN] Mechanical Hardware Clearance...

Technically, the spec you quoted is for uncoated boards. You can thus
interpret it as you wish.

However, like everybody else said, a non-conductive washer is in order
here... 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Abel, Shannon K.
Sent: Thursday, September 21, 2006 11:13 AM
To: [log in to unmask]
Subject: Re: [TN] Mechanical Hardware Clearance...

 It is relavent when my PM is asking.  While I know its not best
practice, I need to find what the correct answer is.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Whittaker, Dewey
(EHCOE)
Sent: Thursday, September 21, 2006 11:01 AM
To: [log in to unmask]
Subject: Re: [TN] Mechanical Hardware Clearance...

IMHO
It is irrelevant whether you violated any guideline or not. Do not ever
mount any conductive entity over a trace which then relies solely on the
SM for electrical protection.
Dewey 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Abel, Shannon K.
Sent: Thursday, September 21, 2006 7:44 AM
To: [log in to unmask]
Subject: [TN] Mechanical Hardware Clearance...

I have a board with a 15VDC trace on the surface layer that runs under a
flat washer.  

The trace is covered by SM, which provides 500vdc isolation per .001 mil
of SM coating. 

2221 states that any electrical conduction trace per sec 6.3 lists a
minimum clearance of .00512 to any other conductive surface (.ie
mechanical hardware)

Do I violate the spec.

Any help would be greatly appreciated.

Shannon Abel





---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2