Thanks Ingemar,

My email seems to have mangled the formatting but yes, I'd be interested
in the whole table. I'm sure it would look very good on my wall too.

Regards,



Ingemar Hernefjord (KC/EMW) wrote:
> Furthermore, I have some values about the cavitation vs. Liquids vs.
> Temperature e.g. Below:
>
>
> Liquid          Formula         Boiling         Max cavitation intensity
> Temperature at which
>                                                                 for 46
> MHz lambda/2            reaches intensity max
>
> 1. Water                H2O             100 C
> 100%                                    35 C
>
> 2. Xylen                C6H4 etc        137 C
> 61%                                     93 C
>
> 3. Ethanol              C2H5OH  78  C                           45%
> 21 C
>
> 4. Aceton               (CH3)2CO        56  C
> 44%                             minus 36 C
>
> Etc
>
> Can send whole table to interested, or for Steve's wall
>
>
> Inge
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of [log in to unmask]
> Sent: den 13 september 2006 20:51
> To: [log in to unmask]
> Subject: Re: [TN] US Cleaning in IPA
>
> 40 MHz was the typical frequency used for augmenting solvent cleaning.
> There is a classic paper by Brandreth & Johnson on removal of a
> standardized particle (diamond dust) published in 1978 as I recall. Will
> send you the exact reference later if you are interested-- let me know.
> 25-28 MHz was more typically used with aqueous systems until we got into
> the more elaborate multi-frequency systems.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
> archives of previous posts at: http://listserv.ipc.org/archives Please
> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
>

--
Eric Christison Msc
Mechanical Engineer
Home Personal, Communication Sector
Imaging Division

STMicroelectronics (R&D) Ltd
33 Pinkhill
Edinburgh EH12 7BF
United Kingdom

Tel:    +44 (0)131 336 6165
Fax:    + 44 (0)131 336 6001

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2