If there is peeling/flaking after they have performed all cure cycles/steps
then I would suspect the reliability of the mask.
Under/over developing in itself is not a major concern in my opinion;
however, if it has removed so much of the mask in fine areas where it
affects adherence of the mask to the board then this leaves the possibility
of mask lifting at some point in the future, this lifting mask may
potentially entrap contaminates thus presenting additional reliability
issues.
Franklin
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kevin Glidden
Sent: Tuesday, September 26, 2006 11:26 AM
To: [log in to unmask]
Subject: [TN] Over-developed Soldermask
Question for the PCB fabricators...
One of our PCB suppliers is asking us to accept PCBs with a "minor" issue.
The problem is described as this: The panels were under-developed and some
residual solder mask was left over. To eliminate this, the panels were put
through a second pass to ensure all residual solder mask was removed. The
result is some overdevelopment of the solder mask. Then, this apparently
resulted in an "undercut" along the demarcation lines. They say during a
tape test, very small traces of mask from the undercuts comes off. The mask
is still present between all features and is adhered to the PCB. But, it
is over-developed and has undercuts. They say that while it does not pass
the tape adhesion test, it is of no detriment to the PCB quality or
performance.
My question is if over-developed soldermask maintains the same properties as
normally developed soldermask? When I asked about this, they said the
properties of the mask are determined by the initial (pre-developing) cure
and the final (post-developing cure), and the over-development does not
affect the properties. True?
In case "it depends", these PCBs are used in avionics power supplies.
Thanks in advance!
Kevin
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|