Hi Dan,
You say:
> We normally like to see finished copper weight on all layers. That way we
> can determine starting copper weight depending upon copper additive process
> (plating) and inner layer processing
>
That does not make much sense to me—how to you control "finished copper
weight", when all you can see in a n x-section is physical thickness.
You need to specify copper weight for the lamination foils used, but
"finished" and "plating" thickness for the product.