Joyce Koo <[log in to unmask]>
Reply To:
Date:
Thu, 10 Aug 2006 13:19:52 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (113 lines)
Agree with Chris.  If you are doing flip chip attach, (line width and
spacing much narrow than normal application), you might need different spec.
As for class 2, it is environmental only... not include consideration of
line spacing and electrical field strength, which may also impact your ionic
migration path.
My 1.7 cents.
                                       jk

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Schaefer, Chris
Sent: Thursday, August 10, 2006 12:42 PM
To: [log in to unmask]
Subject: Re: [TN] Ionic/Chloride contamination levels

Well Francis if you have customers then they may be a source of what is
considered clean or not. If not you can choose the standard IPC 10.06Mg or
come up with what you believe to be clean. Determine how clean is clean for
your business and go with it. We are considering changing ours once again,
but for some customers that want a very specific cleanliness level while
others basically state 'get it clean'. It depends on the type of customers
you have (military, aerospace, commercial, etc...). If you have hi-rel
customers than you need to get them really clean (relative of course), while
consumer stuff not so clean...

Just a few cents worth...

CAS

Chris Schaefer
Suntron Corporation
Process Engineer
540 N. Rogers Road
Olathe, Kansas 66062
913.393.5878
[log in to unmask]

NOTICE:

This message is intended for the use of the individual entity to which it is
addressed and may contain information that is privileged, confidential and
exempt from disclosure under applicable law. If the reader of this message
is not the intended recipient, or the employee or agent responsible for
delivering the message to the intended recipient, you are hereby notified
that any dissemination, distribution or copying of this communication is
strictly prohibited. If you have received this communication in error,
please notify us immediately by calling 913.393.5878 or returning the
original message to us.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Francis Sun
Sent: Thursday, August 10, 2006 11:11 AM
To: [log in to unmask]
Subject: [TN] Ionic/Chloride contamination levels


Hi Forum,

Can anyone tell me what is the general industry acceptance level for
chloride contamination on a assembled board for a class 2 product please.
I am getting conflicting statements from 2 evaluation labs.
One says 6.5ug/in2 is acceptable in the industry.
Another says 3ug/in2 is the industry standard or will/should be the
industry standard.

Is there an IPC committee looking at update the acceptable levels?
Thanks in advance for all inputs, opinions and facts

Regards;

Francis Sun
MARK IV Industries
(905) 624-3025 ext. 1235
Fax: (905) 624-4572

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2