Hi Gabriela,
You bring up some interesting questions. Let me to talk to our engineer in charge of the rework process and get more info. I will post more on this shortly.
Thanks,

Amol Kane
M.S (Industrial Eng.)
Process Engineer
Harvard Custom Manufacturing, Inc. 
941 Route 38  Owego, NY 13827
Phone: (607) 687-7669 x349
Fax: (607) 687-9733
[log in to unmask]
www.harvardgrp.com

 -----Original Message-----
From:   Gabriela Bogdan [mailto:[log in to unmask]] 
Sent:   Saturday, August 26, 2006 3:16 AM
To:     TechNet E-Mail Forum; Kane, Amol (349)
Subject:        Re: [TN] Copper Pad Peel Strength

I wish to add a question.
Did you experience this failure on perhaps mechanically stressed BGA's?
If so, the crack under the pads may be present before rework...
And why do you rework?
Shorts or opens?
Opens may be caused by lifted pads and connector break .
Are the failed pads locations random or on specific locatios?-(CORNERS??)
Gaby
----- Original Message ----- 
From: "Kane, Amol (349)" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, August 25, 2006 2:29 PM
Subject: [TN] Copper Pad Peel Strength


> Dear Technetters,
> We are having instances where copper pads (Under BGAs) are being lifted 
> off ENIG Boards almost too easily during rework. We use the same thermal 
> profile on each board (for the same component removal) and only some show 
> this phenomenon. Is there a test or standard to test the copper adhesion @ 
> incoming to see whether it's the fab (i.e. are the boards coming to us 
> with poor copper adhesion strength to being with) or the process that's 
> doing this. The board is heated upto 120 C when the component is reflowed 
> for removal. Also, is there data to show the decrease in Cu adhesion 
> strength with temp?
>
> Thanks,
>
> Amol Kane
> M.S (Industrial Eng.)
> Process Engineer
> Harvard Custom Manufacturing, Inc.
> 941 Route 38  Owego, NY 13827
> Phone: (607) 687-7669 x349
> [log in to unmask]
> www.harvardgrp.com
>
>
>
>
> CONFIDENTIALITY NOTICE:
> This e-mail, and any attachments, is for the sole use of the intended
> recipient(s) and may contain information that is confidential and
> protected from disclosure under the law. Any unauthorized review, use,
> disclosure, or distribution is prohibited. If you are not the intended
> recipient, please contact the sender by reply e-mail, and delete/destroy
> all copies of the original message and attachments.
> Thank you.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------
> 







CONFIDENTIALITY NOTICE: 
This e-mail, and any attachments, is for the sole use of the intended 
recipient(s) and may contain information that is confidential and 
protected from disclosure under the law. Any unauthorized review, use, 
disclosure, or distribution is prohibited. If you are not the intended 
recipient, please contact the sender by reply e-mail, and delete/destroy 
all copies of the original message and attachments. 
Thank you.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2