The ONLY reason that I can see to change this finish is because of brittle
fracture at the interface between BGA packages and the board.

The reason for this is that an ENIG joint has approximately half of the
shear strength of an AG or HASL joint and the much higher thermal transition
temperature from solidus to room temp can set up destructive shear forces.

It has been very noticeable that a large number of BGA manufacturers have
moved away from ENIG as a finish on the component substrate over the last 2
years.

John

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dave Seymour
Sent: Monday, August 14, 2006 10:33 AM
To: [log in to unmask]
Subject: [TN] Immerison Au vs Immersion Ag

We are having a little talk about surface finish for
RoHS compliance.

We have been doing Immersion Gold for 10+ years and
are starting to switch to Immersion Silver because some feel
that Silver is a better finish for RoHS compliance.

I can't find anything that says one can not be compliant with
Immersion Gold and I'm trying to figure out why the surface finish
should change at all.

Could someone point to some articles, opinions or sources that
might help resolve the issue?

I'm out doing some web looking now.

Thanks
Dave



--
Dave Seymour, CID+
Catapult Communications Inc.
800 Perimeter Park Dr, Suite A
Morrisville, NC 27560

Direct: (919)653-4249
Main: (919)653-4180
Fax: (919)653-4297

[log in to unmask]

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2