No, it should be bigger!

If a blind via is made by a laser as a controlled depth job, the target
pad acts a bit like a "backstop" for the laser.  For this case
"breakout" has the most horrendous consequences:  The dielectric
adjacent to the pad is damaged (perhaps even carbonized) and may plate
during the plating step.  It may be detectable as a short right away, or
may have to wait a while to show up.  I use minimum of 3 mil annular
ring for laser blinds, and other pcb fabricators appear to be in the
same ballpark.

Wayne Thayer

>>> [log in to unmask] 7/16/2006 2:39 am >>>
IPC-6012, Class 3 requires 1 mil minimum internal annular ring for
plated through holes.  Is the internal layer of a blind via bound by
these requirements?

Jay Otts
Raytheon

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2