A good acoustic microscope should be able to find these cracks quickly and
non-destructively.  It is not a cheap tool, though, at $100k-$200k depending
on the options.

On Mon, 5 Jun 2006 10:11:04 -0400, Tempea, Ioan <[log in to unmask]> wrote:

>Hi Technos,
>
>a never ending story, ceramic caps that crack, possibly due to
depanelizing. The damage is not visible, unless the cap is cross sectioned.
>
>Is there any testing, thermal cycling or something like that, that could
show the damage real fast?
>
>Thanks,
>
>Ioan

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2