Hello Graham,
I have just installed a couple of new 10 zone (7 heat, 3 cool) reflow
ovens that we use nitrogen in. We are using approx. 1350-1400 SCFM of
nitrogen per hour to get the PPM of oxygen below 100.
Hope this helps,
Steve

---------------------------------------------------