Peter,
   I'm not sure if you can re-use the hole since the PEM will dig into,
(so to speak) the board. I did want to mention that PEM has 2 different
nuts and that one is specifically made for PCB use. If by chance the
wrong nut was used and it wasn't the one for PCB's, maybe using the
correct nut in both PCB application and length, you might get away with
it? One other thing. Is the nut, when tightened, trying to be pulled
into the board or from the board? If into the board, you may only need
to get the new nut to stay once or twice during assembly since the screw
that goes into it will hold it in the PCB? If it's the other way, I
don't know how well it will work/last/hold. Best of luck...
Later...

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Peter Lee
Sent: Friday, June 09, 2006 10:57 AM
To: [log in to unmask]
Subject: [TN] Reworking PEM nut on PCBA

Does anyone have recommendation on a process to remove self-clinching
PEM nut from the board? An incorrect 4-40 size and 1/4" long nut was
mistakenly installed and needs to be removed and replaced with a similar
but shorter nut.

Would I lose much of the clinching strength by re-using the hole? Is
there any work-around to reinforce the hole to achieve the similar pull
strength as before?

Any suggestion is appreciated.

Rgds,
Peter

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2