Yeah, another "offshore broker". They pull up in the driveway in a
horse-drawn cart, and the components purchasing directer runs out
salivating. 
Supply chain quality management at its best.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Bill Campbell
Sent: Wednesday, June 28, 2006 10:05 AM
To: [log in to unmask]
Subject: Re: [TN] Bad capacitors in Boston Scientific Defibrillators and
Pacemakers...

probably some buyer decided he could save $.35 on a reel of 5000....

On 6/27/06, Stadem, Richard D. <[log in to unmask]> wrote:
>
> Yes. If they are used for military product, this would ordinarily be 
> covered by a GUIDEP alert.
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Reuven ROKAH
> Sent: Tuesday, June 27, 2006 8:58 AM
> To: [log in to unmask]
> Subject: Re: [TN] Bad capacitors in Boston Scientific Defibrillators 
> and Pacemakers...
>
> There is another important question:
> If it capacitor failure: the capacitor supplier should inform were and

> to whom they were sold and to alert the customers who supposed to use 
> them.......
>
> Best  Regards
>
> Reuven  ROKAH
>
> e mail: [log in to unmask]
>
>
>
>              "Tempea, Ioan"
>              <itempea@POSITRON
>              .QC.CA>
> To
>              Sent by: TechNet          [log in to unmask]
>              <[log in to unmask]>
> cc
>
>
> Subject
>              27/06/2006 16:40          Re: [TN] Bad capacitors in
Boston
>                                        Scientific Defibrillators and
>                                        Pacemakers...
>              Please respond to
>               TechNet E-Mail
>                    Forum
>              <[log in to unmask]>
>              ; Please respond
>                     to
>               "Tempea, Ioan"
>              <itempea@POSITRON
>                   .QC.CA>
>
>
>
>
>
>
> I guess there is only one question to be asked: what other sources of 
> this kind of products are there?
>
> Ioan
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Stadem, Richard D.
> Sent: Tuesday, June 27, 2006 9:31 AM
> To: [log in to unmask]
> Subject: Re: [TN] Bad capacitors in Boston Scientific Defibrillators 
> and Pacemakers...
>
>
> I also found the article disturbing. Some of the facts in the article 
> don't quite add up.
>
> They sampled a small percentage. Obviously (I hope) they chose a 
> sample size based on the number of defective assemblies they were 
> seeing that would ensure the problem caps would be detected if 
> present. I assume this was after the fact was discovered. The article 
> states that they did not find any bad caps. Was not the sample size 
> large enough, or is the problem something else? I am assuming there 
> are capacitors from the bad lot still available for inspection.
> All of the bashing of Guidant's processes is not only unprofessional, 
> but also very suspicious. These processes are carefully monitored by 
> medical quality auditors. If the problem was in product released by 
> Guidant and still being manufactured by Boston Sci, how come they did 
> not find the problem, either?
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or
> (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing 
> per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET 
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the 
> archives of previous posts at: http://listserv.ipc.org/archives Please

> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing 
> per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16for additional 
> information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2