Hi Brian,
Your point is welll taken. With RH and moisture content phenomena you can
easily wind up with theshold limits and processes that are not 'accelerations'
from more benign realistic conditions. On the other hand, your stated maximum
values of "100%RH @ ~15°C, ~85% at 25°C, ~75% at 35°C, ~55% at 50°C" appear
somewhat low. Unfortunately, I am on the road and do not have access to my
references, but if i recall correctly, the dew point at 35°C occurs at ~95%RH. As it
is, the absolutr vapor pressure is more important than RH except when
determining the dew point.
Werner
---------------------------------------------------