Hi Badri:
For most of the components it will not make a difference,
whether eutectic or Pb free solder is used, since the majority of them
are Tin finish, no issues. If it is a BGA it will not solder properly
specially at 63/37 reflow temps due to the fact that the solder balls
for the most part are made with 305 SnAgCu solder, which is not very
compatible with 63/37 SnPb. If the metal finish is Nickel Tin is fine or
if it is Bismuth Tin as long as the Bismuth is =< than 3% is also fine.
So check the metal finish of the part.
Regards,
Ramon
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Badri
Sent: Thursday, June 22, 2006 7:22 AM
To: [log in to unmask]
Subject: [TN] lead free compatibility
Hello All,
Can I reflow solder a lead free component (chip components)in the leaded
process/profile. Will there be any solderability issue. Advenace thanks
for the help you are rendering.
Thanx
Badri
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|