This is a standard call out.  I deal with aircraft components where the supplier owns part of the design engineering authority.  For those components our product specification lists certain data that is required as part of the product acceptance test.  We review and approve the supplier Acceptance Test Procedure.  The Supplier's ATP is a controlled document (under revision control and often requires my company's approval if anything changes).  The document number and revision of the ATP is listed onn AS-9102 forms.

Sort of long winded, but listing the document identification and revision level of the equivalent to an ATP is what is being required.  Parts that are shipped without a functional test would list this item as N/A.  I would tend to list bare board continuity tests as N/A.  I suggest you check with your customer to determine their expectation.

Don Vischulis

-----Original Message-----
>From: Franklin D Asbell <[log in to unmask]>
>Sent: May 24, 2006 12:39 PM
>To: [log in to unmask]
>Subject: [TN] AS9102 First Article question
>
>On Form 2 of AS9102 First Article form under 11. Functional Test Procedure
>Number.
>
>
>
>What type 'functional tests' are being asked for on Bare Printed Wiring
>Boards?
>
>
>
>My thought is electrical test and perhaps structural integrity, and welcome
>any and all thoughts on how other shops are handling this requirements.
>
>
>
>Regards,
>
>
>
>Franklin
>
>
>
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2