You guys are awesome!
Many thanks Graham, Kerry, Reuven, and Ioan! 
I really appreciate the insight!
Thanks again.
Will

_____________________________________________
From: Ryan, Will 
Sent: Wednesday, May 10, 2006 8:34 AM
To: [log in to unmask]
Subject: 0402 Experience and Pitfalls

Dear fellow TechNeters,

For many of you this is old technology, and you most likely are focusing
on 0201 implementation or Pb-Free.
However for our team, we are about to make the giant leap from 0603
components to 0402s!

Thus, you guys out there at the cutting edge will have a boat load of
experience to share with regard to the implementation issues and
pitfalls with the introduction of 0402s, and I am hoping that you will
be able to give me the 'skinny'!

Obviously stuff like aperture design, stencil design, nozzle selection,
placement capability, cam speed, AOI, rework, inspection magnification,
etc. will all be affected.
However, what I am looking for are details that would help our
transition sail through, coupled with some unanticipated issues you were
faced with and how they were overcome, e.g. tombstoning, soldering,
placement accuracy, etc. which were not apparent when placing 0603s.

Have you guys had any reliability issues with 0402s?
Also, do you guys use 0402s on the solder-solder side, with a glue and
wave process? Is this a no no?

Would really appreciate if you would be willing to share your
experience.
Best regards,
Will 

 
 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2