Hi Werner!
Good question, one that I'm going to ask around here. Maybe it was a
recommended fluid from RD Technologies? But I did look at what
temperatures Galden offers their fluid at, it's at
http://www.solvaysolexis.com/pdf/gald_vapor.pdf and you can get fluids
at 155, 165, 200, 210, 215, 230, 240, and 260 C.. Do you think that a
240 C. fluid would be better for lead free alloys?
-Steve Gregory-
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier
Sent: Tuesday, April 11, 2006 2:13 PM
To: [log in to unmask]
Subject: Re: [TN] RD Technologies Vapor Phase Users
Hi, Jason & All,
Why would you need LS-260 [I am assuming that means the T=260]; the
whole point of vapor phase is that you can solder at temperatures of
Liquidus+~5C rather than Liquidus+~20-25C
Werner
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|