TECHNET Archives

April 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Jones, Evamaria" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Jones, Evamaria
Date:
Thu, 6 Apr 2006 14:28:03 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (66 lines)
Just a note of caution. A successfully completed repair usually will not meet the full intent of the original requirement (J-STD-001) because form, fit or function required restoration. Successful rework on the other hand is considered reprocessing and usually results in compliance to requirements.
Eva Jones 

________________________________

From: TechNet on behalf of prasad godavarti
Sent: Thu 4/6/2006 10:37 AM
To: [log in to unmask]
Subject: [TN] relationship between J-STD-001 and IPC 7711/7721: need your help.



In a nutshell here is where i need some help:

we call out and enforce J-STD-001, Class 3 on our
assembly drawings. Very often we do repair/rework on
these assemblies and we do not seem to have a clear
link between IPC 7711 and IPC 7721 wherein the
how-to's and what to control are listed and J-STD-001,
Class3. The only words that address repair/rework in
J-STD-001 have to do with the acceptance criteria for
such operations.

Ques:

1. I am reading this correctly?
2. How do i ensure that the repair and rework
procedures and the skill sets are adequate? do I need
to explicitly state in on the drawing the need for
repair and rework per IPC 771 and IPC 7721?

3. If i do not state that then is the compliance to
J-std-001 violated?

Thanks

Prasad Godavarti


__________________________________________________
Do You Yahoo!?
Tired of spam?  Yahoo! Mail has the best spam protection around
http://mail.yahoo.com <http://mail.yahoo.com/> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2