It is a minimum requirement for PCB fabrication to test as a minimum the
cleanliness of the board surface prior to soldermask coating. IPC-TM-650
2.3.25 provides the test method for the Solvent Extract Test.  Telecom
does require some additional testing for SIR testing also - Reference
Telcordia (Bellcore) TA-NWT-000078.  It is also advisable to maintain
cleanliness control and audit programs for Ionic Contamination and SIR
for inner layer cores prior to bonding and post final finish -
specifically HASL.    

Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED 
           76 Technology Drive - POB 1890 
              Brattleboro, Vermont 05302
                Voice - 802.257.4571 ext 21
                    Fax - 802.257.0011
                       <http://www.vtcircuits.com/> 
                           

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kevin Glidden
Sent: Tuesday, April 04, 2006 11:05 AM
To: [log in to unmask]
Subject: [TN] PCB cleanliness prior to soldermask

Is there a spec for testing a bare PCB prior to solder mask application?
Is
it customary to perform an ionic cleanliness test prior to application
of
SM?



Kevin Glidden
Manufacturing Engineer
Luminescent Systems Inc.
4 Lucent Drive
Lebanon, NH 03766-1439
Tel # (603) 643-7766 ext. 3152
Fax # (603) 643-5947



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2