Kevin,

In IPC-A-610 Rev. D, it states clearly, for Class 3, "Minimum heel fillet
height is equal to solder thickness plus lead thickness."

If you have parts where the pad layout spread is larger than your component,
then the larger the difference will get you further away from the acceptable
spec.


Jason Gregory
Manufacturing Engineer
Innova Electronics
(281)653-5593
(281)653-5594 fax
(281)594-0602 cell
[log in to unmask]

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kevin Glidden
Sent: Monday, March 06, 2006 10:29 AM
To: [log in to unmask]
Subject: [TN] Heel Overhang

Hello again.

Question on IPC-610 (class 3) criteria.  For SMT solder joints, there appear
to be criteria set for TOE overhang, but not HEEL overhang.  Is this an
oversite or a purposeful omission?  Is there a limit on how much the heel of
an "L" shaped SMT lead can be off the pad lengthwise?  The obvious and
defined limit is "does not violate minimum electrical clearance", but does
anyone else have info on this criteria?

Thanks again,
Kevin Glidden


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2