I don't understand what you mean by the "then one of the alloy components"
statement. However, if your lab is testing by Sn/Pb standards, then you
should fail the high amount of tin every time.  My lab tests with an SN96.5
spec. What was funny is that one test we "failed" or we were out of spec on
the SN content, but they had inadvertently selected SN96 for the test
instead of SN96.5. Even that minute change threw us off (they corrected it
though), so I think testing to Sn/Pb would make you fail every time.



Jason Gregory
Manufacturing Engineer
Innova Electronics
(281)653-5593
(281)653-5594 fax
(281)594-0602 cell
[log in to unmask]

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joel Mearig
Sent: Thursday, March 30, 2006 11:14 AM
To: [log in to unmask]
Subject: [TN] Maximum Contamination Levels in Solder

I have the solder tested in my solder pots on a regular basis. However, the
testing lab continues to provide results based on Sn/Pb standards even
though the solder is lead-free. The lab clarifies the results with the "if
not one of the alloy components" statement.



I was wondering if there was a different contamination levels chart for
lead-free solder that I could get my testing lab to use.



Any help would be greatly appreciated.



Joel Mearig




---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2