TECHNET Archives

March 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Zilber Gil <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Zilber Gil <[log in to unmask]>
Date:
Tue, 28 Mar 2006 16:58:16 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (179 lines)
Regards, 
Thanks a lot for the answers.



 



Regards,



 



Gil





________________________________



מאת: TechNet בשם Dehoyos, Ramon

נשלח: ב 27/03/2006 20:49

אל: [log in to unmask]

נושא: Re: [TN] Conformal coating and BGA







        Another under fill used is Floropel. Super thin and a little

pricey.

        Ramon



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.

Sent: Monday, March 27, 2006 1:40 PM

To: [log in to unmask]

Subject: Re: [TN] Conformal coating and BGA



To answer further, no conformal coating should ever be applied

underneath a BGA. Some can absorb moisture and swell up, cracking the

solder joints. Do not attempt to use conformal coat as an underfill.

Also, I would not coat the tops of BGAs either, as some (most notably

the metal-top types) have internal or external heatspreaders that will

be insulated due to the conformal coating, causing premature component

failures.

If the danger of shorting is present due to moisture condensation or

other moisture or chemical atmosphere hazards are present, use an

appropriate underfill epoxy formulated for that purpose.



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Macko, Joe @ IEC

Sent: Monday, March 27, 2006 11:37 AM

To: [log in to unmask]

Subject: Re: [TN] Conformal coating and BGA



Gil,



Hello.

I have not heard of any restriction or problems applying c/c to the tops

of BGAs however, this does not coat the solder joints (SJs) located

under the BGA package, which is required by IPC-A-610. So, c/c BGAs does

not apply c/c to the actual SJs located under the package, which

violates IPC-A-610 acceptability requirements. We have used various

wickable underfills to seal SJs located under BGA packages.



joe



-----Original Message-----

From: Zilber Gil [mailto:[log in to unmask]]

Sent: Monday, March 27, 2006 8:17 AM

To: [log in to unmask]

Subject: [TN] Conformal coating and BGA



Hello All,



Are their any restrictions of applying conformal coating on BGA

components (Mil, Jedec, etc.)-i.e. on top of the BGA, avoiding

underneath it, etc.?



Thanks,





Dr. Gil Zilber

Technologist, Elta system Ltd.

Tel. +972-8-8577240

Mobile +972-54-4983222

http://www.iai.co.il/site/en/iai.asp?pi=17887







 The information contained in this communication is proprietary to

Israel Aircraft Industries Ltd.

and/or third parties, may contain confidential or privileged

information, and is intended only for the use of the intended addressee

thereof. If you are not the intended addressee, please be aware that any

use, disclosure, distribution and/or copying of this communication is

strictly prohibited.

If you receive this communication in error, please notify the sender

immediately and delete it from your computer. Thank you.





This message is processed by the PrivaWall Email Security Server.



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 1.8e To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing

per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:

http://listserv.ipc.org/archives Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16

for additional information, or contact Keach Sasamori at [log in to unmask]

or 847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 1.8e To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 1.8e To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 1.8e

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------





This message is processed by the PrivaWall Email Security Server.

















 The information contained in this communication is proprietary to Israel Aircraft Industries Ltd. 

and/or third parties, may contain confidential or privileged information, and is intended only for 

the use of the intended addressee thereof. If you are not the intended addressee, please be aware 

that any use, disclosure, distribution and/or copying of this communication is strictly prohibited.

If you receive this communication in error, please notify the sender immediately and delete it from 

your computer. Thank you. 





This message is processed by the PrivaWall Email Security Server. 





---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2