TECHNET Archives

March 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Graham Collins <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Graham Collins <[log in to unmask]>
Date:
Mon, 27 Mar 2006 09:47:15 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (30 lines)
Hello Technet!
I've got a simple question.  We don't have any sinks available on our
production floor, so if anyone has dirty hands they have to walk a fair
way to the bathroom.  So the other day I was asked if it would be OK if
the production folks used hand wipes, and was handed a container of the
wipes our maintenance guys use.  I'm very reluctant to OK it this
specific one, but I'm wondering if there are any available that are OK
to use in a CCA production environment?  Something that won't leave
nasty residues on a CCA?

Thanks!

regards,

Graham Collins
Process Engineer,
L-3 Communications Electronic Systems Inc.
Halifax
(902) 873-2000 ext 6215

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2