Subject: | |
From: | |
Reply To: | |
Date: | Fri, 24 Mar 2006 14:09:48 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Darrel
I have found that blind and buried vias can be used to compensate for two
and sometimes four layers. Normally, it has been my experience that the
break even price is four layers, but this is highly dependent upon the board
shop. Keep in mind that blind vias usually mean component construction which
is expensive.
Best regards
Lee
J. Lee Parker, Ph.D.
JLP Consultants LLC
804 779 3389
----- Original Message -----
From: "Darrel Therriault" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, March 24, 2006 1:34 PM
Subject: [TN] Blind/Buried Vias
> Technetters,
>
> We have a design that is very dense and routing is going to be a
> challange.
>
> Is there any rule of thumb for gaining routing space by going to blind and
> buried vias relative to standard vias (We can't increase layer count)?
>
> Is there any rule of thumb for a cost increase one would expect to incur?
>
> Any info appreciated.
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
> Thanks....DJT
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives