http://www.teledyne-ai.com/oem/diving.html

The R22D or R22DHO have molex kk 3 terminal contacts. These respond to partial pressure of O2 so the response varies in
proportion to (O2 concentration)*(pressure). The diving ones have a high rejection to condensation and surface contamination.

Lifetime 21% O2 @ STP should be good for 3 years. Somewhat less at ~1ATM partial pressure O2 with ambient pressures in excess of
15ATM!

Generally the R22D response from new is 9mV to 11mV in air after allowing a few hours to waken up if straight out of the
package.

Best Regards

David Greig
______________________________
GigaDyne Ltd
Buchan House
Carnegie Campus
Dunfermline KY11 8PL
United Kingdom
t: +44 (0)1383 624 975
www.gigadyne.co.uk
______________________________

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: 21 March 2006 20:12
To: [log in to unmask]
Subject: [TN] Oxygen sensor

Can anyone recommend a good oxygen sensor that can be used to verify the level of a nitrogen blanket? I am looking for one that
can be used to verify the oxygen percentage inside of the reflow oven, or on a rework station, or within a nitrogen box used for
storage of components.
Thanks for any responses.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC
web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
--
Virus scanned by Lumison.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2