Hi all,
One of the designers came with an idea: he has a high power component.
The space he has for a heat sink is small, so he wants to dissipate the
heat through the power layers. The component is a BGA, so the idea is to
put it on a metallic-capped via-in-pad by designing pad diameter of 24
mils, then define the solder area to 18 mils by solder mask.
Two questions:
1.      Provided the temperature may rise to 120 degC, and the laminate
is high Tg low cost FR4 - are there any potential risks to the long term
reliability?

2.      Are there any restrictions/hazards on deployment of defined
pads?

Regards
Ofer Cohen
Manager - Quality Assurance and Reliability
SIEMENS COM FN A SB

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2