Donald Vischulis <[log in to unmask]>
Reply To:
Donald Vischulis <[log in to unmask]>
Date:
Wed, 8 Feb 2006 19:28:44 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (85 lines)
The specification is suspect.  All high voltage tests (insulation resistance or dielectric withstand) that I've encountered are specified as test voltage, test time, and maximum allowable leakage current.  I don't understand how the resistance affects the test parameters.

Don Vischulis

-----Original Message-----
>From: Jeffrey Bush <[log in to unmask]>
>Sent: Feb 7, 2006 3:20 PM
>To: [log in to unmask]
>Subject: Re: [TN] Hi voltage testing
>
>Talk to Associated Research - they provide a host of units and good
>technical guidance on DWV testing.  The test (HYPOT)is mainly to
>validate power/ground leakage that will cause units to fail.  I have
>seen some Avionics customers that either need all nets validated or a
>series of critical nets tested.  Design will have an impact on test
>failures also.
>
>Jeffrey Bush
>Director, Quality Assurance and Technical Support
>VERMONT CIRCUITS INCORPORATED
>           76 Technology Drive - POB 1890
>              Brattleboro, Vermont 05302
>                Voice - 802.257.4571 ext 37
>                    Fax - 802.257.0011
>                       <http://www.vtcircuits.com/>
>
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Kelly
>Sent: Tuesday, February 07, 2006 3:22 PM
>To: [log in to unmask]
>Subject: [TN] Hi voltage testing
>
>Fellow Technetters,
>We have been asked by a customer to do a dielectric withstanding voltage
>on a flex circuit. The requirement is 500Vdc at 5000 ohms. I have a
>couple of questions: 1) who supplies such equipment and 2) I am under
>the impression they want this on every net on every circuit - isn't this
>normally some coupon or AQL basis? Thanks in advance. Regards Steve
>Kelly
>
>
>Steve Kelly
>PH: (416) 750-8433
>FAX: (416) 750-0016
>CELL: (416) 577-8433
>
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text
>in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at:
>http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
>ext.2815
>-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2