TECHNET Archives

February 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Stadem, Richard D." <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Stadem, Richard D.
Date:
Tue, 28 Feb 2006 14:08:38 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (129 lines)
The solution may be as simple as adding a spacer under the connector to
allow for inspection.  

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Schaefer, Chris
Sent: Tuesday, February 28, 2006 1:02 PM
To: [log in to unmask]
Subject: Re: [TN] Solder Joint Inspection

Section 6.3.1 speaks about a 50% vertical hole fill on sections of the
board that are considered thermal planes or conductor planes. It sounds
like this applies, but it may require something from your customer to
allow this or for reasons of stress it is required - not sure. We have
issues such as your and we have spoken with the customer and have
received the ok to allow a 50% fill versus the traditional 75%.

I agree with the previous point, but it will not allow for any process
anomalies that occur on occasion. If for some reason the connector has
issues related to the solderability, then you have a problem. In another
scenario if the area/ connector has not been proper fluxed or achieved
proper solder contact - it might look fine on the outside, but has not
achieved the solderability levels you desire.

Food for thought...

Have a nice day guys!

Chris Schaefer
Suntron Corporation
Process Engineer
540 N. Rogers Road
Olathe, Kansas 66062
913.393.5878
[log in to unmask] 

NOTICE:
 
This message is intended for the use of the individual entity to which
it is addressed and may contain information that is privileged,
confidential and exempt from disclosure under applicable law. If the
reader of this message is not the intended recipient, or the employee or
agent responsible for delivering the message to the intended recipient,
you are hereby notified that any dissemination, distribution or copying
of this communication is strictly prohibited. If you have received this
communication in error, please notify us immediately by calling
913.393.5878 or returning the original message to us.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of John Berg
Sent: Tuesday, February 28, 2006 12:44 PM
To: [log in to unmask]
Subject: Re: [TN] Solder Joint Inspection


If x-ray is not an option, you need to set up a soldering process that
would not require inspection. On a thermally relieved pad that does not
get sufficient fill, you need to preheat the pad area prior to hand
soldering to compensate for the heat sinking. If you can get a dummy
populated board, preheat it to a known reference level, and then remove
the connector body to examine the % fill. Find the minimum reference
preheat that will obtain your desired % fill. If you can't get a dummy
populated board, you can use a few production boards to find the
reference preheat by utilizing an ouitside x-ray service to determine
the % fill.

>>> [log in to unmask] 2/28/2006 7:55 AM >>>
We are having a heck of a time inspecting some solder joints and could
use your help.

Per Class 3 a solder joint is supposed to have at least a 75% fill. We
have a circuit board that has large ground planes and hand soldered
connectors that are impossible to inspect for top side solder.

We do not have access to an x-ray and are wondering if there are any
clever ways to inspect these solder joints.

Thanks,

KennyB

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2