TECHNET Archives

February 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Dehoyos, Ramon" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Dehoyos, Ramon
Date:
Fri, 3 Feb 2006 09:21:31 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (108 lines)
        Hi John:
        If there is a concern in damaging the balls or the SJ interface,
there should be a concern in damaging the pads and also crushing the
laminate and decreasing the distance between layers. Another approach
would be to support the BGA from the four sides and allowing the
pressure to be exerted on the sides of the BGA only. Making a fixture
where four thin long steel plates, one for each side, would be
positioned under the BGA sides to support it( there are other ways to
support the BGA). After which the heat sink is placed and pressed on the
BGA.
        Just a thought.
        Ramon
 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Leo Higgins
Sent: Thursday, February 02, 2006 7:15 PM
To: [log in to unmask]
Subject: Re: [TN] PSA heat sink attachment

I do not know the "safe" load level.  This is likely dependent upon a
lot of factors with the ball pitch and ball/pad size being very
important.  Another major issue is keeping the board very flat during
pressure application.  I have seen the use of pneumatically "controlled"
presses in assembly lines, where the pressure went too high and the
substrate fell from the board leaving all the balls nicely attached to
the PCB.  This was not a case of ENIG black pad.  I would use the lowest
possible pressure and make sure the system elements are coplanar and
well supported during load.


Best regards,
Leo

Leo M. Higgins III, Ph.D.
Vice President, Technical Support Operations ASAT, Inc.
3755 Capital of Texas Highway, Suite 100
Austin, Texas     78704

office phone   512-383-4593
mobile           512-423-2002
[log in to unmask]
www.asat.com


The information contained in this electronic message is
CUSTOMER/SUPPLIER PRIVILEGED AND CONFIDENTIAL INFORMATION intended only
for the use of the individual or entity named above. If the reader of
this message is not the intended recipient, you are hereby notified that
any dissemination, distribution and copying of this communication is
strictly prohibited. If you have received this communication in error,
please immediately notify the sender by electronic mail. Thank you.



-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of John S. Berg
Sent: Wednesday, February 01, 2006 10:34 PM
To: [log in to unmask]
Subject: [TN] PSA heat sink attachment


We are attaching heat sinks to BGA's using a pressure sensitive adhesive
tape product. The recommended application pressures seem on the high
side based on some of our BGA part ball counts. Does anyone know the max
safe psi loading on a BGA ball/pad interface? The balls are eutectic and
the ball/pad interfaces are ENIG. Thanks in advance for help on this.

John Berg

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2