Jon,

The hole size mechanics shown in the tables are intended to provide
sufficient room for successful solder wicking at the extremes of hole
variation. My experience has shown that some insertion machine
manufacturers specify larger hole sizes so that they can hit the
insertion cycle times that they advertise for their machines. In
practice, most machines can hit the insertion cycle times with smaller
holes than recommended. In other words, the recommended holes are "safe"
  holes that meet the advertised cycle times.

Regards,

Gary Ferrari
Ferrari Technical Services
860-350-9300

Jon McDowell wrote:
> Technetters
>
> I have a question for you
>
> We are loading a component with a lead diameter of .032 +/-0.002 into a
> hole that is .042 +/- 0.003.
>
> On page 20 of IPC-2222 it states in tables 9-4 and 9-5 that with a
> tolerance of +/-0.004 the max over sizing in respect to the lead
> diameter (on the min side of tolerance) is +/-.023.  Can anyone explain
> the reason behind these numbers.
>
> We are using an Panasonic AVKII which call for the hole to be oversized
> 0.019 from the maximum lead tolerance.
>
> Why would IPC and Panasonic specs not match, this puts us in a difficult
> position.
>
>
> Any help would be appreciated.
>
> Thank You
> Jon McDowell
> Electronic Controls Co (ECCO)
> 833 W Diamond St
> Boise Id 83705
> P 208 395-8025
>
>
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
>
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2