I do not know the "safe" load level. This is likely dependent upon a lot of
factors with the ball pitch and ball/pad size being very important. Another
major issue is keeping the board very flat during pressure application. I
have seen the use of pneumatically "controlled" presses in assembly lines,
where the pressure went too high and the substrate fell from the board
leaving all the balls nicely attached to the PCB. This was not a case of
ENIG black pad. I would use the lowest possible pressure and make sure the
system elements are coplanar and well supported during load.
Best regards,
Leo
Leo M. Higgins III, Ph.D.
Vice President, Technical Support Operations
ASAT, Inc.
3755 Capital of Texas Highway, Suite 100
Austin, Texas 78704
office phone 512-383-4593
mobile 512-423-2002
[log in to unmask]
www.asat.com
The information contained in this electronic message is CUSTOMER/SUPPLIER
PRIVILEGED AND CONFIDENTIAL INFORMATION intended only for the use of the
individual or entity named above. If the reader of this message is not the
intended recipient, you are hereby notified that any dissemination,
distribution and copying of this communication is strictly prohibited. If
you have received this communication in error, please immediately notify the
sender by electronic mail. Thank you.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of John S. Berg
Sent: Wednesday, February 01, 2006 10:34 PM
To: [log in to unmask]
Subject: [TN] PSA heat sink attachment
We are attaching heat sinks to BGA's using a pressure sensitive adhesive
tape product. The recommended application pressures seem on the high side
based on some of our BGA part ball counts. Does anyone know the max safe
psi loading on a BGA ball/pad interface? The balls are eutectic and the
ball/pad interfaces are ENIG. Thanks in advance for help on this.
John Berg
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|