Scott,
I've been reading the posts replying to this question. From your
description and the responses from others, the problem sounds very much to
be a copper plating issue. Specifically, super saturated air in the plating
solution causes this. Pits, mouse bites or whatever you want to call them
are one of the reasons more advanced shops have gone to airless agitation in
their copper plating baths.
One of the dry film suppliers did a huge study on this years ago when pits
were a general problem and driving board fabs crazy trying to find a
solution. No question that developing/rinsing issues can exacerbate the
problem. Further, some films will develop OK but leave a sidewall that has
striations that can catch and hold air bubbles. If you've looked at the SEM
of a resist sidewall you can see that some films are worse than others in
how clean their sidewalls look after developing. Simply turning off the air
in a plating bath and running boards as a test won't really work unless your
fab lets the bath sit for 24 hours (without any air agitation) to properly
de-gas.
Sincerely,
Roger Mouton
EIMC - Advanced Plating Technologies
www.smartcatshield.com
[log in to unmask]
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|