Hi, on a related note...we are looking for a XRF too... can you share the manufacturer's details and pricing on the XRF you have??

Amol Kane
M.S (Industrial Eng.)
Process Engineer
Harvard Custom Manufacturing 
941 Route 38  Owego, NY 13827
Phone: (607) 687-7669 x349
[log in to unmask]

 -----Original Message-----
From:   TechNet [mailto:[log in to unmask]]  On Behalf Of Tempea, Ioan
Sent:   Friday, January 06, 2006 9:39 AM
To:     [log in to unmask]
Subject:        [TN] How to use XRF?

Hi Netters,

we've just become the happy owners of a tabletop XRF analyzer. Works fine, shows what we need, we have already rejected non-compliant parts, etc.

But there is a litle something... The soft allows for creating applications, so we can declare that the component has layers, i.e. you can define Au over Ni over Cu. At this moment the measurements will tell you what is the thickness of each layer and what is the composition of each layer. Normally this increases the accuracy of the measurements.

If I x-ray considering layers, I get readings for a SnPb layer that show 14% lead. If I don't use the layered routine and I shoot through the bulk of the surface, the Pb goes away, the influence of the Ni and mainly of the Cu dilutes the Pb to below RoHS threshold.

Hence the question, how should I measure? What is the homogeneous material, each layer or the bulk?

Thanks,
Ioan

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2