TECHNET Archives

January 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Babcock John <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Babcock John <[log in to unmask]>
Date:
Tue, 31 Jan 2006 08:39:43 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (56 lines)
It sounds like a board warpage problem on the larger design.  Can you up
the thickness (0.093" or 0.125") on the design to add a little strength
and reduce the warping?  I've seen under extreme temp. cycling that the
extra thickness on the PCB helps warping thus reducing cracked
components.  This wouldn't be a problem on the smaller boards 2" x 2"
due to it doesn't fluctuate that much with warping.

Just an idea.
John

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Nutting
Sent: Tuesday, January 31, 2006 8:32 AM
To: [log in to unmask]
Subject: [TN] Large SMT physical failure prevention


Good morning,
 
We have some designs that are calling for large, 1825 and 2225
components.  We have seen some mechanical failures where the parts have
cracked.  If we need to use these monster components, how do we ensure
we reduce or eliminate the mechanical failures.
 
Our failures were seen on a 16 inch by 17 inch 0.062 thick board.  On
these we have changed our handling methods.
 
On smaller 2 inch by 2 inch boards is this a don't care?  I know that
rapid temperature ramp up or down in the reflow process could be a
killer.  Something to work out with our CM.
 
Phil

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2