Of course, but he was asking which standard allowable tolerances were
identified in, and that would be those documents...

I did not see in the message where he was looking for fabrication
capabilities or design metrics.

Franklin



-----Original Message-----
From: Jeffrey Bush [mailto:[log in to unmask]]
Sent: Wednesday, January 25, 2006 8:19 AM
To: [log in to unmask]
Subject: RE: [TN] Soldermask Tolerance

Just to interject - IPC-6012/600 only provide the allowable soldermask
on land areas by annular ring or pitch dimension of SMT.  When needing
to understand the PCB fab capability during design, these standards do
not offer guidance as they are dependant on specific fabricator
capabilities.  IPC-2221 does provide a clearance metric, which is .13
mm, but should also be considered in conjunction with interconnect
design and materials selection.

Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED
           76 Technology Drive - POB 1890
              Brattleboro, Vermont 05302
                Voice - 802.257.4571 ext 37
                    Fax - 802.257.0011
                       <http://www.vtcircuits.com/>


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Franklin D Asbell
Sent: Wednesday, January 25, 2006 8:28 AM
To: [log in to unmask]
Subject: Re: [TN] Soldermask Tolerance

Brian,

Review IPC 6012 and IPC-A-600, these will provide text and images of
solder
mask registration allowances.

Franklin

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Brian Pulis
Sent: Wednesday, January 25, 2006 6:17 AM
To: [log in to unmask]
Subject: [TN] Soldermask Tolerance

hi all,

does anyone know if there's a standard which specifies the maximum
allowable
soldermask shift for non-soldermask defined pads.


regards

> Brian Pulis
> Process Engineer
>
> Dedicated Micros Malta Ltd.
> UB2, San Gwann Industrial Estate,
> SGN 09. MALTA.
>
> Tel: (+356)23819 187/199
>
> Fax: (+356)23819 100
>
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2