Subject: | |
From: | |
Reply To: | |
Date: | Wed, 25 Jan 2006 08:56:36 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Brian
I believe there is a requirement in the Bellcore spec.
I prefer a note on the drawing that requires one mil clearance between the soldermask and the copper feature. To achieve this the soldermask normally needs to be registered to within three mils of the panel's datum.
Best regards
Lee
J. Lee Parker, Ph.D.
JLP Consultants LLC
804 779 3389
----- Original Message -----
From: Brian Pulis<mailto:[log in to unmask]>
To: [log in to unmask]<mailto:[log in to unmask]>
Sent: Wednesday, January 25, 2006 7:16 AM
Subject: [TN] Soldermask Tolerance
hi all,
does anyone know if there's a standard which specifies the maximum allowable
soldermask shift for non-soldermask defined pads.
regards
> Brian Pulis
> Process Engineer
>
> Dedicated Micros Malta Ltd.
> UB2, San Gwann Industrial Estate,
> SGN 09. MALTA.
>
> Tel: (+356)23819 187/199
>
> Fax: (+356)23819 100
>
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|