RO 4350 has a lower bond strength when compared to FR4.  TO combat this,
a higher profile foil is used to improve the peel performance.  When the
PCB house uses 4350 in a foil build and is bonding with RO 4450, the
foil treatment needs to be specific to maintain bond strengths.  Not
using the correct foil type will produce poor bond strengths which maybe
a learning curve for the PCB house.  

If the build is a core build, with RO4350 from L1/2: Ln/Ln-1, then the
bonding mechanism is controlled by Rogers.  The PCB supplier should be
able to interface with Rogers to obtain the lot testing information and
assess of the peel numbers are out of specification.  

A microsection of the PCB will also show the foil profile
characteristics and determine the build used.

Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED 
           76 Technology Drive - POB 1890 
              Brattleboro, Vermont 05302
                Voice - 802.257.4571 ext 37 
                    Fax - 802.257.0011
                       <http://www.vtcircuits.com/> 
                           

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Thursday, January 19, 2006 5:09 PM
To: [log in to unmask]
Subject: Re: [TN] PWB SMT pad retention

The boards are made of Rogers 4350 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Sherif Refaat
Sent: Thursday, January 19, 2006 11:31 AM
To: [log in to unmask]
Subject: Re: [TN] PWB SMT pad retention

Hi Richard,

What kind of laminate is that? I had similar problem, few years ago,
repairing boards built using "Thermount" (Aramid). That was one of the
draw backs of this laminate. The new version of "Thermount" suppose to
be better in terms of peel strength, but I don't know if it is close
enough to that of FR4.

Sherif Refaat,

----- Original Message -----
From: "Stadem, Richard D." <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, January 19, 2006 11:42 AM
Subject: [TN] PWB SMT pad retention


Hi, Folks,
Is there a standard that specifies how well SMT pads should adhere to
the pwb? By pads I mean BGA pads that have no trace attachment, and I.C.
(gullwing) pads.
A client has circuit boards with pads that come off extremely easily
during standard rework and reflow processes. It is not limited to the
BGA pads, many other unused I.C. lead pads are also being found out of
place in the solder joints after reflow, and are easily peeled away. The
pads are not tiny flip chip pads, but standard .035" diameter pads and
rectangular .020" by .030" pads. The reflow peak temperature is only 210
deg. C for about 40 seconds. The rework is at 200 C. for 30 seconds.
Also, any speculation on the cause? This problem is limited to a single
PWB part number.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2