Hi Richard,

What kind of laminate is that? I had similar problem, few years ago,
repairing boards built using "Thermount" (Aramid). That was one of the draw
backs of this laminate. The new version of "Thermount" suppose to be better
in terms of peel strength, but I don't know if it is close enough to that of
FR4.

Sherif Refaat,

----- Original Message -----
From: "Stadem, Richard D." <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, January 19, 2006 11:42 AM
Subject: [TN] PWB SMT pad retention


Hi, Folks,
Is there a standard that specifies how well SMT pads should adhere to
the pwb? By pads I mean BGA pads that have no trace attachment, and I.C.
(gullwing) pads.
A client has circuit boards with pads that come off extremely easily
during standard rework and reflow processes. It is not limited to the
BGA pads, many other unused I.C. lead pads are also being found out of
place in the solder joints after reflow, and are easily peeled away. The
pads are not tiny flip chip pads, but standard .035" diameter pads and
rectangular .020" by .030" pads. The reflow peak temperature is only 210
deg. C for about 40 seconds. The rework is at 200 C. for 30 seconds.
Also, any speculation on the cause? This problem is limited to a single
PWB part number.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2