What is the name of the company with the $6k machine.  Cookson has quoted me a $12-14k machine depending on 'options'.


Andrew Kettlewell
Sr Process Engineer
Sypris Electronics
Tampa, Fl



-----Original Message-----
From: McGee, Mike (MN51) <[log in to unmask]>
To: [log in to unmask]
Sent: Tue, 10 Jan 2006 15:55:14 -0600
Subject: Re: [TN] Manual conformal coat dipping process


You can get auto dip equipment for around $6K. It is a worthwhile
investment.
Got ya's - Dip slowly (2"/min or less) to avoid bubble entrapment.
Withdraw at the same slow rate. The slower you withdraw the thinner the
coating. Too fast and you will have coating dripping off the card. We
would usually hang them for 5 minutes and brush off the drips as they
formed.
We used a machine set at about 1"/min. The boards were small so we could
dip 6 at a time.

-Mike McGee

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joseph H. Smith
Sent: Tuesday, January 10, 2006 3:41 PM
To: [log in to unmask]
Subject: [TN] Manual conformal coat dipping process

Fellow technetters.

Anyone out there have experience with 'manually' dip coating conformal
coat.  I have never done the dipping coating process.  Machine spray and
hand spray I have done.  The concept sounds simple enough but I was
looking for advice on process got ya's or issues to watch for when doing
the dipping.  Our customer is requiring the dipping process and
currently doesn't wish to spend the money on more automated equipment.

Andrew Kettlewell
Sr Process Engineer
Sypris Electronics
Tampa, Fl
___________________________________________________
Try the New Netscape Mail Today!
Virtually Spam-Free | More Storage | Import Your Contact List
http://mail.netscape.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
___________________________________________________
Try the New Netscape Mail Today!
Virtually Spam-Free | More Storage | Import Your Contact List
http://mail.netscape.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2