Actually they aren't very similar at all.  Edge fingers are relatively easy
to do because they can be connected to a tie bar off the edge of the panel
to provide the connectivity to different nets for the electrolytic plating.


For wirebonding, it's almost impossible to do this without complex tie-bar
removal processes.

Mike McMaster
DFM Engineer
Merix Corporation
Phone  503-992-4263
Mobile  503-720-3277
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ryan Grant
Sent: Monday, December 05, 2005 10:11 AM
To: [log in to unmask]
Subject: Re: [TN] How to prevent solder mask peeling problem for ENIG+ENEG
circuit boards

No, you're right.  Linda said wire bonded sites, but the processes are
similar.

-----Original Message-----
From: Eddie Rocha [mailto:[log in to unmask]]
Sent: Monday, December 05, 2005 10:40 AM
To: TechNet E-Mail Forum; rgrant
Subject: Re: [TN] How to prevent solder mask peeling problem for
ENIG+ENEG circuit boards

I'm sorry, I don't know why but I was thinking wire bonded
sites not edge connectors?

Thank you,
Eddie Rocha
South Bay Circuits


Hi Eddie,

All of my boards are electrolytic Ni and Au AFTER
soldermask, and I
won't have it any other way!  Soldermask doesn't stick well
to gold so
it should be coated directly to copper.  Even coated on
copper there can
still be adhesion problems.  Soldermask formulations that
hold up well
to both the immersion gold plating and electrolytic gold
plating have
been around for decades.

Linda,

There are many formulations of soldermask that work well
with any of the
gold processes.  I was surprised to find out that all of my
suppliers,
(spanning three continents), all used Taiyo PSR-4000 as
their primary
soldermask supply.  Most of them use the exact same process
you
described to mask off the board for selective gold plating
of edge
connector tabs.  The "old" way is to use blue tape instead
of dry film,
to mask off the board where gold is not wanted.

If your supplier doesn't know how to fix your current
problems, that is
a huge red flag you are using a shop that doesn't know what
they are
doing.  In the interim, until you find a new shop, or get
your current
one to figure out the dry film process, have them use the
"old" way and
mask off the board using blue tape. (But make sure they
don't use a
knife to trim the tape.  I've had shops cut my traces
trying to trim the
tape.)

Regards,
Ryan

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Eddie
Rocha
Sent: Monday, December 05, 2005 9:08 AM
To: [log in to unmask]
Subject: Re: [TN] How to prevent solder mask peeling
problem for
ENIG+ENEG circuit boards

Actually I can't figure out how you plate electrolytic Ni
and Au after soldermask or why? Could you explain?
Thank you,
Eddie Rocha
South Bay Circuits


Hello Eddie,

Thanks for your good idea.

Can you explain how to process Electrolytic Ni and Au
plating before LPI solder mask in detail?  I can't figure
out how it is done.

Best regards,

Linda Li


-----Original Message-----
From: Eddie Rocha [mailto:[log in to unmask]]
Sent: Saturday, December 03, 2005 12:59 AM
To: TechNet E-Mail Forum; Li, Linda
Subject: Re: [TN] How to prevent solder mask peeling
problem for ENIG+ENEG circuit boards


I would have used the following sequence of processes:
 Electrolytic Ni & Au plating before LPI soldermask, etch
the outer layer image, LPI soldermask, peelable mask (to
protect the electrolytic gold features, then ENIG. I
wouldn't expect soldermask adhesion problems with this
approach.

Thank you,
Eddie Rocha
South Bay Circuits


Hello all,

We have a design using ENIG plus ENEG surface finishing on
circuit boards, ENIG is used for Al wire bonding, ENEG is
used for Au wire bonding.  We met 2 problems about this
design.

1) We found solder mask peeling problem after aging the
assembled circuit boards at 150 degree C for 2 hours.  We
contact the circuit board supplier and were told that
because of 2 times UV exposure( 1 time is in solder mask
exposure, the other is in ENIG process), the solder mask
was apt to peel off.  So far the supplier doesn't have any
good method to solve this problem.   Do you have any
suggestions to solve this problem?  Thanks.
2) During ENIG process, the gold is seeped onto the surface
of copper pad that needs to be electrolytic gold plated.
  It's because of air bubble entrapped during dry film
lamination.  The supplier has changed the lamination speed,
processed the panels in different direction, but still
can't solve the problem.   I am in urgent need of your
expert advice .

The circuit board fabrication process flow is as follows:
 >> solder mask printing>>dry film lamination>> UV
exposure>>dry film development>>Electroless Nickel
Immersion gold plating>>strip dry film resist>>Electrolytic
nickel and gold plating>>

Thanks for your help in advance!

Best regards,

Linda Li




************************************************************************
****************

Note:  If the reader of this message is not the intended
recipient, or an employee or agent responsible for
delivering this message to the intended recipient, you are
hereby notified that any dissemination, distribution or
copying of this communication is strictly prohibited. If
you have received this communication in error, please
notify us immediately by replying to the message and
deleting it from your computer. Thank you.

************************************************************************
****************

---------------------------------------------------
Technet Mail List provided as a service by IPC using
LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

************************************************************************
****************

Note:  If the reader of this message is not the intended
recipient, or an employee or agent responsible for
delivering this message to the intended recipient, you are
hereby notified that any dissemination, distribution or
copying of this communication is strictly prohibited. If
you have received this communication in error, please
notify us immediately by replying to the message and
deleting it from your computer. Thank you.

************************************************************************
****************

---------------------------------------------------
Technet Mail List provided as a service by IPC using
LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using
LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with
following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send
e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send
e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using
LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2