.048 +/-.003 if a.051 is not too sloppy

At 02:32 PM 12/02/2005, you wrote:
>We've had problems with this in the past so maybe the group can help me
>out.
>
>I have a mill-max receptacle pin with a .040 diameter.  The datasheet
>calls for a .042 minimum dia. plated through hole.
>
>Is it better to call out a .048 hole with a +/- .003 drill tolerance?
>(because if you stack the .003 positional tolerance as well, you could
>get down to the min. .042 hole).
>Or is it better to call out a .047 hole with a +/- .002 drill tolerance?
>(because with the .003 positional tolerance you could get down to the
>min. .042 hole).
>
>Or does this depend on which board house you go to as well?
>
>John
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2