Don't use chemicals unless you can strip the complete PWA and clean it with an in-line cleaner.  The chemicals can become trapped under components and cause electrical shorts since some of these are conductive.  If the area is small, use heat only.  Better yet, switch to type AR coatting.
  ----- Original Message ----- 
  From: Joseph H. Smith<mailto:[log in to unmask]> 
  To: [log in to unmask]<mailto:[log in to unmask]> 
  Sent: Tuesday, December 13, 2005 9:47 AM
  Subject: [TN] Help with removing UR Conformal Coating


  Has anyone had experience or success with removing conformal coating for PWA that has been coated with UR coating especially using a chemical means.  I am particularly interested with how you handled coating around or under BGA's.

  Any help would be grateful.


  Thanks.

  Andrew Kettlewell
  Process Engineer
  Sypris Electronics
  Tampa, FL
  ___________________________________________________
  Try the New Netscape Mail Today!
  Virtually Spam-Free | More Storage | Import Your Contact List
  http://mail.netscape.com<http://mail.netscape.com/>

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
  -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2