Hi Charlie,
Yes, that would serve. We have "PTH/PTV Reliability Coupons," "Registration
Coupons" and "SIR Coupons"--why not "Delamination Coupons." At this point, it
is however not clear, at least to me, which PWB design features [lots of Cu,
little Cu, coupon size, etc.] are the most critical in terms of lamination.
But my question is as 'Why should the burden not be on the suppliers?'--they
control the properties of their materials and it should be part of their data
sheets. Unfortunately, data sheets are made of very uncomplaining paper--I
have found data sheets from large 'reputable' suppliers giving CTE values of FR-4
material as low as 11 ppm/C when the true CTE when we measured it was almost
double.
Why is it, that in our industry, most of the suppliers are part of the
problem rher than part of the solution?
With this 'Lead-Free' insanity and the lack of resources, we had better all
contribute or face the consequences.

Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2