http://www.ul.com/pwb/LeadfreeAndPresentationProceedings.pdf
page 38. what do they point at then?
Inge
-----Ursprungligt meddelande-----
Från: TechNet [mailto:[log in to unmask]] För Werner Engelmaier
Skickat: den 14 december 2005 20:56
Till: [log in to unmask]
Ämne: Re: [TN] SV: [TN] Qualification of the Pb-free capable
manufacturers
Hi Inge,
I do not know abput UL's proposal, but there are some defined
conditions:
T260, T288, T300 & T320 defining temperatures at which time to
delamination is
measured up to 45 minutes--I also do not know who came up with this
measure
[288°C???]. Standard FR-4 has a T260 of less thasn 30 minutes and a T288
of less
than 5 minutes, whereas a high Tg/highTd material has a T288 of 45
minutes and
a T320 of about 25 minutes.
Werner
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------