TECHNET Archives

November 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Phil Nutting <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Phil Nutting <[log in to unmask]>
Date:
Wed, 30 Nov 2005 11:48:28 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (114 lines)
That was my thought too.

I did a little more web surfing and found a Tech-Spray product called
Licron(r) 1755 listed as a permanent Static Dissipative Coating.  Looks
like a cured on coating. 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Roach, David
Sent: Wednesday, November 30, 2005 11:15 AM
To: [log in to unmask]
Subject: Re: [TN] Anti static sprays

The anti-static sprays are temporary, so they have to be re-applied
regularly.  I am not sure how long they last, as I have limited
experience
with them.  It would be best to check their effectiveness regularly with
an
electrostatic field strength meter.

On a related note, in a former life, we purchased some new
static-dissipative (blue) plastic totes.  We sent them through an
aqueous
cleaner before sending them into a clean room.  When we tested them,
they
had no static dissipative properties.  The manufacturer said that the
anti-static properties are removed by washing, but that the plastic
would
"bloom" and eventually become dissipative again.  Our tests showed that
this
never happened.  I believe they may have treated the molded plastic
parts
with an anti-static spray to call them dissipative, though I have no way
to
prove this.  (This was about 8 years ago, so the properties of new
products
may be different.)  On the other hand, conductive totes are molded with
carbon in the plastic resin, so they should remain conductive over their
life.  The conductive totes have higher conductivity than static
dissipative
totes (especially after being washed :-) ).

Dave Roach

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Nutting
Sent: Wednesday, November 30, 2005 10:04 AM
To: [log in to unmask]
Subject: [TN] Anti static sprays

Has anybody used any of the available anti static sprays to reduce
"static ticking" in a high voltage environment?

On doing a web search I see there are many products on the market, but
are these really for ESD control?.  The question is, do I have to keep
re-spraying the item to keep it functioning or is it a one time
application?

Thanks in advance.

Phil Nutting
Design for Manufacturing Engineer
Kaiser Systems, Inc.
126 Sohier Road
Beverly, MA 01915
voice: 978-922-9300 x1310
fax: 978-922-8374
e-mail: [log in to unmask] <mailto:[log in to unmask]>
www.kaisersystems.com <http://www.kaisersystems.com/>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2