Hi Antonio,

The max thickness should not exceed 6 micron. Any reflow stage add about
2 micron to the intermetalic layer.

Regards,

Dr. Gil Zilber
Technologist, Elta system Ltd.
Tel. +972-8-8577240
Mobile +972-54-4983222
http://www.iai.co.il/site/en/iai.asp?pi=17887



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of antonio
Sent: Monday, November 28, 2005 12:56 PM
To: [log in to unmask]
Subject: [TN] Intermetalic Layer

Please

Does anyone know how thick an intermetalic layer should be for tin/lead
and leadfree ?

Thanks

Antonio/INPE/Brazil

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


This message is processed by the PrivaWall Email Security Server.



 The information contained in this communication is proprietary to Israel Aircraft Industries Ltd.
and/or third parties, may contain confidential or privileged information, and is intended only for
the use of the intended addressee thereof. If you are not the intended addressee, please be aware
that any use, disclosure, distribution and/or copying of this communication is strictly prohibited.
If you receive this communication in error, please notify the sender immediately and delete it from
your computer. Thank you.


This message is processed by the PrivaWall Email Security Server.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2