Hello all,

To add some data regarding this case, all the failures correspond to
trace cracking at a fold line. Most cracks locate at a pad to trace
junction on an "arm" of the flex board, but one trace next to the holes
is also cracked at the fold line. All the junctions are filleted and the
base copper is RA. The cracks occur during integration. The "arms" of
the flex board has waves (i.e. other folding lines).
I am wondering whether these waves are normal, or if they are due to a
poor design, a poor copper ductility or a poor flexure of the polyimide
material, or....

Any insight will be welcome.

Best regards.


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


ATOM RSS1 RSS2