                                Hi Kenny!

                                Good suggestion, but I'm wondering how tedious is would be to
                                apply the coating and not get it all over the leads. The coating that
                                gets applied is a urethane coating...we use Conap CE-1155 and it'll
                                take a few reflow cycles with no discoloring at all...I've tried it.

                                The coating idea won't work for all parts though. I know some of the
                                DC/DC converters (from Interpoint I believe) cannot have any coating
                                on them at all due to heat dissapation requirements.

                                I've called and talked with Kyzen, and the 4512P should not affect the
                                marking. On the occasions that the marking has come off, it has done
                                so by flaking off, or come off in the piece of tape that we've covered it
                                with trying to protect it. So it looks like we're going to have to go through
                                the long and tedious process of taking this issue up with the component
                                manufacturers...and it's more than just a few. If it were Kyzen affecting the
                                markings, they would be dissolving off, not flaking.

                                I appeciate Les Bogert's response in regards to using a label, but that
                                means you have to record the date code and serial number of the part
                                before building the assembly so that you can record accurate information
                                on the label if you need one later...just more paperwork. But, if you gotta',
                                you gotta'....

                                Kind regards,

                                -Steve Gregory-
                                Senior Process Engineer
                                LaBarge Incorporated
                                Tulsa, Oklahoma
                                (918) 459-2285
                                (918) 459-2350 FAX





        "Bloomquist, Ken" <[log in to unmask]>
                        Sent by: TechNet <[log in to unmask]>
                        11/07/2005 12:59 PM
                        Please respond to TechNet E-Mail Forum <[log in to unmask]>; Please respond to "Bloomquist, Ken" <[log in to unmask]>
                                	
        To:     [log in to unmask]@SMTP@Exchange
        cc:     (bcc: Stephen R Gregory/LABARGE)
        Subject:        Re: [TN] Component marking on metal parts...	


                                Hi Ramon,

                                It's been quite a while since we did this but to the best of my
                                recollection (it's tough getting older)I believe we applied conformal
                                coating to component ID after reflow and before any wet processing.

                                KennyB

                                -----Original Message-----
                                From: Dehoyos, Ramon [mailto:[log in to unmask]] 
                                Sent: Monday, November 07, 2005 10:49 AM
                                To: TechNet E-Mail Forum; Bloomquist, Ken
                                Subject: RE: [TN] Component marking on metal parts...

                                        Hi Kenny:
                                                        Didn't the CC discolored, or better yet darkened
                                after the reflow oven? I ask this question since the baking temp for CC
                                is a lot lower than the reflow temp. I am all for it, if it works. I am
                                just curious.
                                        Regards,
                                        Ramon 

                                ---------------------------------------------------
                                Technet Mail List provided as a service by IPC using LISTSERV 1.8e
                                To unsubscribe, send a message to [log in to unmask] with following text in
                                the BODY (NOT the subject field): SIGNOFF Technet
                                To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
                                To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
                                Search the archives of previous posts at: http://listserv.ipc.org/archives
                                Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
                                -----------------------------------------------------



                                __________________________________________________________________
                                This message may contain information that is privileged and confidential to LaBarge, Inc.  It is for use only by the individual or entity named above.  If you are not the intended recipient, you may not copy, use or deliver this message to anyone.  In such event, you should destroy the message and kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2