Subject: | |
From: | |
Reply To: | |
Date: | Tue, 15 Nov 2005 07:38:33 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Jim, send me the stack-up specifics and I will check the model for you. I
have 2 different modeling programs.
At 07:28 AM 11/15/2005, you wrote:
>Hello,
>
>If there are any impedance testing gurus out there I have a question for
>you. We are testing an edge coupled offset strip line coupon. We modeled
>the stack up to give us 100 ohms differential. When we test the coupon we
>get around 130 ohms. We have done a microsection of the coupon and modeled
>the coupon data and Polar says we should have 105 ohms, within tolerance.
>We had a 4 panel lot and it is consistent across the board. The coupon is
>constructed correctly. My question is, other than what I am seeing on the
>microsection should I look for to find the culprit of the high reading? Any
>help would be great.
>
>Jim Henderson
>Colonial Circuits
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>for additional information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|