Mil-P-55110E Table IX lists equivalence factors for 4 alternate methods. The equivalence factor for the Omegameter is 1.39. I don't know how accurate this factor is. I'm sure Brian has contributed on this subject in the past. Try the archives.

Geoff   

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Macko, Joe @ IEC
Sent: Wednesday, October 26, 2005 3:28 PM
To: [log in to unmask]
Subject: [TN] Omegameter to IPC-TM-650, Method 2.3.25 cross reference


Fellow techs,



Good morning.

We have an Omegameter 600SMD that is used to check boards for ionic
contaminates.  The ionic residue limit within J-STD-001C, para. 8.3.6 is 10
ug/sq. NaCl.  Some personnel believe that this number should be adjusted
based on the actual instrument used (e.g., an Omegameter).  Would someone be
so kind as to comment on this subject and what the correct limit is for an
Omegameter type of instrument.



Thanks

joe


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

Private & Confidential:

This e-mail message is confidential and is intended solely for the person or organisation to whom it is addressed.  If the message is received by anyone other than the addressee please return the message to the sender by replying to it and then delete the message from your computer.

 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2